Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional

Product Details
Customization: Available
Type: Fire Alarm
Anti-theft Alarm System Approach: Networked
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Export Year
1999-02-01
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
  • Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Related Products
Overview

Basic Info.

Model NO.
ZD1000-16
Anti-Theft Alarm System-Wide
Wire Alarm Detectors
Anti-Theft Alarm System Distance
Common Detectors
Types of Smoke Detectors
Photoelectric Smoke Style
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Ceiling
Combustible Gas Detector Model
NA-300
Item
Fire Alarm System
Alarm Zones
4/8/16
Input Voltage
110 Acv ~240 AC
Normal Operating Voltage
Nominal 24 VDC
Wire Size
Minimum #14 AWG (2.0 mm2) with 600V Insulation
Battery
Lead Acid Only
Relay Contact Rating
2.0 AMPS @30 VDC
Transport Package
Color Box
Specification
CE, RoHS
Trademark
ZUDSEC
Origin
Shenzhen, China
HS Code
853110
Production Capacity
500000PCS/Year

Product Description

Product Description


4/8/16 Zones Conventional Fire Alarm System

Conventional Fire Alarm Control Panel:
ZD1000
 automatic fire alarm system-typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control with remote notification capability-can provide early warning of a developing fire.


The ZD1000 is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices.  The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad.  It also supervises all wiring, AC voltage and battery level.
 
FACP Number of Detection Zones Number of Sounder Outputs Output Delay Settings
ZD1004 4 1 N/A
ZD1008 8 2 N/A
ZD1016 16 4 N/A
Optional model: 
ZD1000-8:  16 Zone, 2 Sound Output
ZD1000-8:  8 Zone, 2 Sound Output
ZD1000-4: 4 Zone, 1 Sound Output 

 
Features
-  4,8,16 Class B Initiating Device Circuits (IDCs)
All zones accept conventional detectors and any normally open contact device
- Four Class B Notification Appliance Circuits (NACs)
- One Form-A Alarm Relay
- One Form-A Trouble Relay
- One Form-A Supervisory Relay
- 3.0 amps of system power 
- Max 20 conventional detectors in one zone.
- Auto/Manual mode setting enable walk test.
- Each Zone can be disabled,
- Sound output can be disabled.
- Manual active sound output enabled.
- Designed with standby batteries and space provision for two sealed lead-acid batteries.
- Testing and disable functions.
 
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Product Parameters

AC Power : 220 VAC, 50 Hz, 2.3 amps

Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation
Battery (lead acid only) 
Maximum Charging Circuit: Normal Flat Charge-27.6V @ 0.8 amp
Maximum Charger Capacity: 18 Amp Hour batter
Sound Output Device Circuits 
General Alarm Zones 1 through 16
Operation: All zones Class B
Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
Alarm Current: 15 mA threshold
Short Circuit Current: 42 mA maximum
Maximum Loop Resistance: 100 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
Standby Current: 7.26 mA
Three Relays Output
Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)
Nonresettable 24 VDC Power 
Maximum ripple voltage: 10 mVRMS          
Operating Voltage nominal 24 volts
Total DC current available from this output is up to 500 mA 
Recommended maximum Standby current is 150 mA

Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional



Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional


 
Related Products

Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional
Smoke Security Conventional Fire Alarm System with 4/8/16 Zones Optional

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier